lookilex.blogg.se

Msa millennium gas mask
Msa millennium gas mask







In order to pass CBRN requirements and tests, the Millennium needed to be made of a material that would not lose its integrity when exposed to hydrogen nitride and other corrosive blister agents. The chief advantage the Millennium has compared to the MCU-Series, is in its use of Hycar nitrile rubber as the primary mask material instead of Butyl or Silicone, which was introduced on the Advantage 1000 in early 1990s. The resulting gas mask system, which used a very similar yet improved design and improved materials, would eventually be called the MSA Millennium. To simplify research and development, the mask's design was derived from the industrial MSA Advantage 1000 gas mask, which in turn is a civilian version of MCU-2/P that they were selling to the US Air Force and Navy. MSA, which was one of the industry leaders involved in the creation of the new standards, developed one of the first masks that would meet and exceed these standards. Chief among the standards that had to be met were prolonged resistance against NBC agents, mask penetration and permeation, field of view, equipment interoperability and ability of equipment to operate reliably (at least 15 minutes) in environments with very high concentrations of chemical agents (including hydrogen sulfide and nitride, which damages silicone-based materials and masks). Army Edgewood Chemical Biological Center.

msa millennium gas mask

The new standards were released in conjunction with tests and results derived by the U.S. The National Institute of Occupational Safety and Health (NIOSH), which was new back then, first released the CBRN standard on March 7, 2003. This would eventually be known as the "CBRN compliant" classification. Because of this, and the ongoing threat of terrorist-deployed NBC agents, the US Government, Mine Safety Appliance (MSA) and related industries accelerated ongoing research on developing a new set of very stringent standards that would define protective clothing and respiratory systems. The Millennium® CBRN gas mask is designed to be used as a system, and while the thread and gasket meet the specifications of the standard, only MSA-manufactured components are tested and certified as assemblies.After the terrorist attacks of 9/11, the respiratory health issues encountered by the first responders (from all the dust and smoke) who didn't have adequate protection and the anthrax mails which followed shortly after, it was clear that there were inadequacies with the current equipment available to first responders. The CBRN canister contains chemical sorbents and a P100 filter to attract, retain and neutralize contaminants. The dual-canister mount allows weapon sighting from either shoulder. A butyl-coated nylon hood is available for total head protection. A standard mechanical speaking diaphragm is included, or MSA’s optional ESP® II communications system can be added. A fully elastic, six-point head harness promotes easy on/off and adjustment, with no hair pulling.

msa millennium gas mask msa millennium gas mask

An internal nose cup with two check valves deflects air from the lens and reduces fogging.

msa millennium gas mask

A drinking tube provides connection for fluid ingestion in contaminated atmospheres. A flexible, one-piece polyurethane lens with a wide field of vision is bonded to the durable Hycar rubber facepiece. DescriptionCombines high performance, customized fit, comfort and cost efficiency in a version of the reliable military-style gas mask (MCU-2/P) used by the U.S.









Msa millennium gas mask